What is tb345-05
TB345-05 is a Barrier Strip Terminal Block with 10 positions, suitable for screw panel mounting, with a maximum current of 45A and a voltage level of 600V. TB345-05 is a terminal block provided by Eaton Bussmann Electrical Division, which belongs to a type of barrier terminal block. It has 10 positions, suitable for screw panel mounting, with a maximum current carrying capacity of 45A and a voltage level of 600V, which makes it suitable for electrical systems that require high current and high voltage handling. As a well-known brand in the electrical industry, Eaton Bussmann's products are known for their high quality and reliability. As a member of its product line, TB345-05 will undoubtedly provide users with stable and safe electrical connection solutions.
Eaton Bussmann TB345 series panel mount terminal block connector, Breakdown voltage 7500V, 600V, 45A, Double row, barrier, Five-pole, #10-32 TPI Screw, Screw, Black, Tin-plated brass terminal, Zinc-plated Steel philslot screw
TB345-05 Parameters
Part Number: TB345-05 |
Category: Terminal Blocks - Barrier Blocks |
Manufacturer: Eaton |
Description: CONN BARRIER STRIP 5CIRC 0.562" |
Package: - |
Series: Magnum? TB345 |
Features: Flange |
Number of Circuits: 5 |
Current Rating: 45A |
Color: Black |
Pitch: 0.562" (14.27mm) |
Voltage Rating: 600V |
Wire Gauge: 8-22 AWG |
Number of Rows: 2 |
Terminal Block Type: Barrier Block |
Number of Wire Entries: 10 |
Top Termination: Screws |
Bottom Termination: Closed |
Barrier Type: 2 Wall (Dual) |
Package_case: - |
What are the advantages of tb345-05
The advantages of TB345-05 include its safety, durability, and versatility.
Safety: TB345-05 has passed safety certifications such as UL, CSA, CE, and IEC, ensuring its safety in various usage environments. In addition, its material has a flame retardant rating of UL94 V-0, which further improves its safety performance.
Durability: The product uses high-quality metal materials, has high durability, can adapt to various working environments, and ensure long-term stable operation.
Versatility: TB345-05 has stepless speed change and forward and reverse adjustment functions, which can meet different usage needs, whether it is screwing, unscrewing, or drilling wood, metal, brick walls, tiles, and plastics.
Application of tb345-05
The application of TB345-05 mainly involves the use of terminal boards, especially in the supporting use of the intelligent steam turbine overspeed protection card FW345. The TB345 terminal board can connect three FW345 cards to provide them with speed signals, oil switch trip signals and emergency stop signals, and provide overspeed protection "three-choose-two" output (dry contact) terminals on the terminal board. This configuration is designed to ensure that all wiring is correct, as incorrect wiring may cause major accidents. The design and specifications of the TB345 terminal board ensure safety and reliability, and provide users with detailed instructions and necessary technical support through standard packaging and provided technical documentation.
FAQ about TB345-05
Power supply failure: This may be caused by poor contact of the power supply line or unstable power supply voltage. Solutions include checking whether the power supply line is in good contact, reconnecting loose power lines, and taking voltage stabilization measures to solve the problem of unstable voltage.
Controller failure: Damage to the controller circuit board or abnormal software may cause the drive to not work properly. Solutions include checking and replacing damaged controller circuit boards, reinstalling or repairing abnormal software, and ensuring good contact of the controller interface.
Motor failure: Internal short circuit, open circuit, or poor connection with the drive may cause the drive to not work properly. Solutions include checking whether the motor is short circuit or open circuit, replacing damaged motors, and ensuring good contact between the motor and the drive.
Encoder failure: Poor contact of the encoder line or damage to the encoder may cause the drive to not work properly. Solutions include checking whether the encoder line is in good contact, replacing damaged encoders, and ensuring good contact between the encoder and the drive.